From:                              route@monster.com

Sent:                               Thursday, January 28, 2016 5:16 PM

To:                                   hg@apeironinc.com

Subject:                          Please review this candidate for: OSP Engineer

 

This resume has been forwarded to you at the request of Monster User xapeix03

William Biette 

Last updated:  07/28/14

Job Title:  no specified

Company:  no specified

Rating:  Not Rated

Screening score:  no specified

Status:  Resume Received


San Antonio, TX  78245
US

Quick View Links:

Resume Section

Summary Section

 

 

RESUME

  

Resume Headline: Field Tech II

Resume Value: 7u4cgqnydjpnpvzq   

  

 

William B Biette

1115 Arrowhead Trail, San Antonio, TX 78245-1041

wbiette@gmail.com

Home 210-674-0450, C-Phone 210-860-4037

SUMMERY

I have over 20 years of Field and Network experience.  From working with local & government agencies in order get permits and understanding of the work that will be involved.  Meeting with the property owner/custodians to complete a well rounded requirements of events that will be set for milestone and adjustments as needed.  I offer a substantial knowledge of large Network Operations in order to have a successful reliable product.

 

Physical Experience:

·               NOC Engineer I, Monitored and maintained service for 120+ cell site.  Monitored for alarms from E-bands, Eclipse Radios and True Point 5200 & 6500, and Cielo radio’s.  Monitored alarms because low RSL’s because of poor weather or equipment failure/ODU or RAC/DAC card failure. Monitored local power for disruption causing battery alarms. Site management for open door alarms to determine schedule or authorized access. 

·               Worked as Outside Plant (OSP/ISP) Field Engineer, maintaining present US communication, working with end user and network administrators, NCC & TCF/NOC to correct loss of service on fiber network.  Investigating Cisco 2950/2970/6500 Access/Distro switches for layer one service.  Activation of services: MDU/Secured Secret Internet/DSN telephone access, along with standard internet/VOIP/telephone.

·               OSP Engineer, responsible for meeting with the building management/commanders.  Acquirement permits from major cell/local and governments agencies, for digging/manhole access/building penetration.  Buried utilities locations gas/electric/sewer/water/telephone.

·               Training of United States Army/Marines to preformed site survey, structured cabling, j-hooks, and installation of Telephone Copper & Fiber Optic Systems. Termination of 2-pr up to 2400-pr copper and from 6stran up to 288+ stran single mode fiber.  Project review to ensure requirements will meet the current needs of the customer.  Locate fiber & copper plant to avoid construction accidents.  Teach as needed when an unknown part of the installation was encountered. 

·               Field test equipment use includes Sunrise Telecom Sunset Test set and Analyzers, JDSU Test set and OTDR, JDSU T-Bird, Fluke Data Analyzer, these are just a few of many types available. Power meters used most often were Noyes OPM and  Fluke.

·               Spliced copper with pick-a-bonds and 710 equipment.  Fiber was spliced with various fusion equipment.  Test and termination of 25pr to 66 blocks, 110 blocks, and Krone modular termination.

·               With blue prints in hand; perform site survey to determine cable path in floors and ceiling, install J-Hooks and Ap’s. Install and termination & testing of Cat5, 5A, 6, at office locations and various patch panels and switches. Termination and test of Cat 5/6 to Panduit Minicom & Leviton wall mount jacks. 

·               3M hot melt and some uni-cam fiber connectors, SC/ST/LC used most often.

·               Follow Bell Core/BICSI industry/construction standards within local policys.

·               Responsible for isolation of communication problems up to and including: Voice Grade/AD/DS0/DDS/DS1/DS3/OC-192 system.

·               Worked directly with customer and vender and local exchange carrier to isolate and solved user problems.

·               Knowledgeable of WAN/LAN/Data switched and voice switched operation.

·               Knowledge of IP testing  (I.E. Ping, FTP, etc.) through routers and gateways for fault isolation.  Coordinated with engineering on  

·               Schematics deficiencies for customer and network efficiency.

·               Provisioning of DS0 thru OC192/DWDM systems, with test and turn up of services, work with Engineers/Venders form customer or company.

·               Assisted with the training of lesser skill set technicians with test set software and application of frame relay switch operation.

·               Experienced in the following DACCS (Digital Access Cross Connect Systems ): DSC; 1x0; ESC; 1x0; 5500 Tellabs; Alcatel 1630 and 1631 3x0.

·               Experienced in the following voice switches Nortel DMS 250/500 DEX 600/400. Data switches: ATM; Cisco BPX, MGX8850, Lucent CBX500; Frame relay; Lucent STDX 9000 edge switches

·               Experienced with the following software for testing and monitoring networks, Centest 550/650, React & React with GUI, ITS (Integrated Test Systems ), HP open view. Solar Wind.

·               Proactive monitoring of carrier and enterprise networks, create and update trouble tickets for outage events.

·               Provide remote support with installing, troubleshooting, and maintaining telecom and data networks.

 

Software: Engineering programs, Convergence, Hats, Red Line, F&E, A&D, knowledgeable of various Windows operating systems for network use. Solar Winds, Apple operating systems. Remedy Ticketing Systems

 

Professional Activities / Organizations:

CompTIA Network+, Study underway

Certificate of Completion, Cisco Systems Intro to Cisco Router Configuration, September 3, 1999

Certificate of Completion, Frame Relay (120 hrs), February 26, 1999, MCI/WorldCom.

Certificate of Completion, High Speed Frame Relay (40 hrs), April 23, 1999, MCI/WorldCom.

Certificate of Completion, Introduction to ATM/Frame Relay & SMDS, July 27, 1998,WorldCom.

Certificate of Completion DSC Translations 108, March 7, 1997, DCS, Dallas TX.

 

 

 

 

William B Biette

1115 Arrowhead Trail, San Antonio, TX 78245-1041

wbiette@gmail.com

Home 210-674-0450, C-Phone 210-860-4037

 

 

Honors and Achievements:

U.S. Forces Garrison Command 645th Regional Support group Certificate of Appreciation 14 March 2012

UNITED STATES MARINE CORPS, letter of appreciation, March 2007-December 2007.

 

Our MCI office received ISO 9000 Certificate.

I was recognized and awarded  the flowing my everyday work efforts.

November 2003 Circle of Stars,

June 2002, Customers’ Choice Award 2002

September 2002, Circle of Stars

February 15 2001 Circle of Stars,

September 1999, Ambassadors’ Club for 1998.

 

Certificate of training: CSC Engineering Installation Team Chief Course ( 61 hrs ) July 23 1993.

Command policy, concerning, project review & changes. Installation inspection of project materials pick up and delivery at host location. Project changes requested by host and adjustment of completion time.

 

Certificate of training: Apprentice cable splicing project/maintenance ( 592 hr ) February 20 1991

Basic telephone cable splicing, color code, aerial splicing, underground splicing, buried splicing, manhole entry, cable vault entry, cable testing before installation & after installation.  Copper splicing and fiber optic splicing mechanical and fusion.  Fiber optic termination SC/LC/ST in to patch panels.

 

Certificate of training: Standard installation Practices training, Outside Cable Plant (30hrs) June 29 1991

Unit recap of OSP safety procedures and Manhole & Cable vault access. Current methods use for splicing AMP/Pick a bonds/710. Identify copper and fiber cable. TRD use for testing cable. Reviewing project drawing & required work permit. Cable locating.

 

Certificate of training: Standard Installation Practices Outside Plant/Fiber Optic July 12 1991

Local unit policy concerning man hole entry & cable vault safety. Current splicing methods, fusion & mechanical. Reviewing project drawing and fiber cable locating. OTDR testing of cable before & after installation.

 



Additional Info

BACK TO TOP

 

Current Career Level:

Experienced (Non-Manager)

Work Status:

US - I am authorized to work in this country for any employer.

 

 

Target Company:

Company Size:

 

Target Locations:

Selected Locations:

US-TX-San Antonio